Hospital Grade Isolation Transformers

Hospital Grade Isolation Transformers

Hospital-grade line noise reduction and spike suppression

Isolation transformers are designed to provide superior line noise reduction and spike suppression, eliminating the need for a dedicated AC line.

120 Volt

Model #: IS250HG

Part #DescriptionSugg.
Resale
Lashen's
Price each
6 or
More
IS250HG250 Watt FULL ISOLATION. Transformer with Faraday shield. UL 60601-1 Listed. 2 hospital-grade outlets and hospital-grade plug.  $ 188.00  $ 167.34  $ 157.50 
Model IS250HG 250 watt Hospital Grade Isolation Transformer
  • Complete line isolation, noise filtering and surge suppression is ideal for sensitive equipment
  • 250 watts, 2 outlets, 6-ft. power cord
  • Hospital-grade plug and receptacles
  • 2-year limited product warranty

Tripp Lite Isolator series UL2601-1 listed Hospital Grade isolation transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. Internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. Isolation transformer with Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps. Secondary neutral to ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients, and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes. Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS250HG includes 2 widely spaced NEMA5-15R hospital grade output receptacles, a 6-ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for placement in any industrial, medical, office or network environment.

  • PLUG / OUTLETS: Input: NEMA 5-15P Hospital-Grade / Output: 2 NEMA 5-15R Hospital Grade
  • ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle)
  • FORMAT: Upright tower
  • ISOLATION: Transformer based line isolation with Faraday shield
Model IS250HG 250 watt Hospital Grade Isolation Transformer Rear View

Features:

  • Tripp Lite's IS250HG Hospital Grade isolation transformer offers line isolation, continuous noise filtering and enhanced common mode surge suppression.
  • Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line
  • Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas.
  • Reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps
  • Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment
  • Serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades
  • Removes EMI/RFI noise, utility switching transients, load generated harmonics and ground loops
  • Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes
  • Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels
  • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
  • Includes 2 widely spaced NEMA5-15R hospital grade output receptacles, a 6-ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch.
  • Rugged all-metal unit housing ships ready for upright tower or wallmount placement in any industrial, medical, office or network environment
  • 2-year limited product warranty

Package Includes:

  • IS250HG Isolation transformer system
  • Instruction manual with warranty information

Model #: IS500HG

Part #DescriptionSugg.
Resale
Lashen's
Price each
6 or
More
IS500HG500 Watt FULL ISOLATION. Transformer with Faraday shield. UL 60601-1 Listed. 4 hospital-grade outlets and hospital-grade plug.  $ 271.00  $ 242.31  $ 228.06 
Model IS500HG 500 watt Hospital Grade Isolation Transformer
  • Complete line isolation, noise filtering and surge suppression is ideal for sensitive equipment
  • 500 watts, 4 outlets, 6-ft. power cord
  • Hospital-grade plug and receptacles
  • 2-year limited product warranty

Tripp Lite Isolator series UL2601-1 listed Hospital Grade isolation transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. Internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. Isolation transformer with Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps. Secondary neutral to ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients, and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes. Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS500HG includes 4 widely spaced NEMA5-15R hospital grade output receptacles, a 6-ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for placement in any industrial, medical, office or network environment.

  • PLUG / OUTLETS: Input: NEMA 5-15P Hospital-Grade / Output: 4 NEMA 5-15R Hospital Grade
  • ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle)
  • FORMAT: Upright tower
  • ISOLATION: Transformer based line isolation with Faraday shield
Model IS500HG 500 watt Hospital Grade Isolation Transformer Rear View

Features:

  • Tripp Lite's IS500HG Hospital Grade isolation transformer offers line isolation, continuous noise filtering and enhanced common mode surge suppression.
  • Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line
  • Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas.
  • Reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps.
  • Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment
  • Serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades
  • Removes EMI/RFI noise, utility switching transients, load generated harmonics and ground loops
  • Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes
  • Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels
  • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
  • Includes 4 widely spaced NEMA5-15R hospital grade output receptacles, a 6-ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch.
  • Rugged all-metal unit housing ships ready for upright tower or wallmount placement in any industrial, medical, office or network environment
  • 2-year limited product warranty

Package Includes:

  • IS500HG Isolation transformer system
  • Instruction manual with warranty information

Model #: IS1000HG

Part #DescriptionSugg.
Resale
Lashen's
Price each
6 or
More
IS1000HG1000 Watt FULL ISOLATION. Transformer with Faraday shield. UL 60601-1 Listed. 4 hospital-grade outlets and hospital-grade plug.  $ 425.68  $ 378.87  $ 356.58 
Model IS1000HG 1000 watt Hospital Grade Isolation Transformer
  • Complete line isolation, noise filtering and surge suppression is ideal for sensitive equipment
  • 1000 watts, 4 outlets, 6-ft. power cord
  • Hospital-grade plug and receptacles
  • 2-year limited product warranty

Tripp Lite Isolator series UL2601-1 listed Hospital Grade isolation transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. Internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. Isolation transformer with Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps. Secondary neutral to ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients, and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes. Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS1000HG includes 4 widely spaced NEMA5-15R hospital grade output receptacles, a 6 ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for placement in any industrial, medical, office or network environment.

  • PLUG / OUTLETS: Input: NEMA 5-15P Hospital-Grade / Output: 4 NEMA 5-15R Hospital Grade
  • ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle)
  • FORMAT: Upright tower
  • ISOLATION: Transformer based line isolation with Faraday shield
Model IS1000HG 1000 watt Hospital Grade Isolation Transformer Rear View

Features:

  • Tripp Lite's IS1000HG Hospital Grade isolation transformer offers line isolation, continuous noise filtering and enhanced common mode surge suppression
  • Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line
  • Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas
  • Reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps
  • Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment
  • Serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades
  • Removes EMI/RFI noise, utility switching transients, load generated harmonics and ground loops
  • Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes
  • Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels
  • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
  • Includes 4 widely spaced NEMA5-15R hospital grade output receptacles, a 6-ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch
  • Rugged all-metal unit housing ships ready for upright tower or wallmount placement in any industrial, medical, office or network environment
  • 2-year limited product warranty

Package Includes:

  • IS1000HG Isolation transformer system
  • Instruction manual with warranty information

Model #: IS1800HG

Part #DescriptionSugg.
Resale
Lashen's
Price each
6 or
More
IS1800HG1800 Watt FULL ISOLATION. Transformer with Faraday shield. UL 60601-1 Listed. 6 hospital-grade outlets and hospital-grade plug. $ 645.00  $ 574.32  $ 540.54 
Model IS1800HG 1800 watt Hospital Grade Isolation Transformer
  • Complete line isolation, noise filtering and surge suppression is ideal for sensitive equipment
  • 1800 watts, 6 outlets, 6-ft. power cord
  • Hospital-grade plug and receptacles
  • 2-year limited product warranty

Tripp Lite Isolator series UL2601-1 listed Hospital Grade isolation transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. Internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. Isolation transformer with Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients, and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes. Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS1800HG includes 6 widely spaced NEMA5-20R hospital grade output receptacles, a 6 ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for upright tower or wallmount placement in any industrial, medical, office or network environment.

  • PLUG / OUTLETS: Input: NEMA 5-20P Hospital-Grade / Output: 6 NEMA 5-20R Hospital Grade
  • ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle)
  • FORMAT: Upright tower with keyhole flanges for wall mount placement
  • ISOLATION: Transformer based line isolation with Faraday shield
Model IS1800HG 1800 watt Hospital Grade Isolation Transformer Rear View

Features:

  • Tripp Lite's IS1800HG Hospital Grade isolation transformer offers line isolation, continuous noise filtering and enhanced common mode surge suppression.
  • Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line
  • Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. -Reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps.
  • Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment
  • Serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades
  • Removes EMI/RFI noise, utility switching transients, load generated harmonics and ground loops
  • Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes
  • Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels
  • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
  • Includes 6 widely spaced NEMA5-20R hospital grade output receptacles, a 6 ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch
  • Ships with NEMA5-20P input plug installed, package includes NEMA5-15P user installable hospital grade replacement plug for compatibility with common 15A wall receptacle
  • Rugged all-metal unit housing ships ready for upright tower or wallmount placement in any industrial, medical, office or network environment
  • 2-year limited product warranty

Package Includes:

  • IS1800HG Isolation Transformer
  • Replacement NEMA5-15P replacement plug
  • User manual with warranty information