Leviton's Lev-UPS' On-Line series is our top-of-line range. Featuring state-of-the-art technology, these models are ideal for the most critical and power sensitive applications. By nature of their double-conversion design, On-Line devices provide the best level of power protection available. Connected equipment is not only immune to even the slightest power fluctuations, it is also protected from most other power anomalies such as spikes, surges, noise, extended under- and over-voltages, harmonics and frequency variations.
All On-Line models feature a wide input voltage tolerance and provide output with less than 3% total harmonic distortion. Twin microprocessors aid redundancy and an automatic bypass switch ensures that power to the load is not interrupted in the event of a UPS fault.
All models come with Leviton's "Lev-WARE™" power-monitoring & UPS-control software at no additional cost. The unique energy saving "Sleep Mode" reduces the cost of ownership and the "Cold Start" feature allows the UPS to be used as a small emergency power source. Also unique to Leviton is remote signaling of basic functions such as Power Normal, Backup Mode & Low Battery states as well as Remote Shutdown, via the standard RS-232, DB-9 connection.
The units feature a user-friendly and aesthetically pleasing multifunction LCD display that indicates various UPS parameters and states along with audible alarms. The inclusion of a hardwire input and output connection terminal block makes these units ideal for industrial and telecom applications. They are also suitable for extended run-time applications.
| Model | |||||||
|---|---|---|---|---|---|---|---|
| U1000-ONL | U2000-ONL | U3000-ONL | U1000-ORM | U2000-ORM | U3000-ORM | ||
| Input | Capacity | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | 1000VA/700W | 2000VA/1400W | 3000VA/2100W |
| Voltage | 120V+/-27%, single phase | ||||||
| Frequency | 50 or 60Hz +/-5% | ||||||
| Power Factor | < 0.98 | ||||||
| Output | Voltage (on battery) | 120V+/-2% Pure sine wave output | |||||
| Frequency (battery) | 50 or 60Hz +/-0.5% | ||||||
| Harmonic Distortion | <3% T.H.D. with linear loads | ||||||
| Power Factor | 0.7 | ||||||
| Efficiency | 85% | ||||||
| Transfer Time | 0 milliseconds, power failure or recovery & bypass mode | ||||||
| Protection and Filtering | Transient Protection | Response time: < 5nsec. Tested to ANSI/IEEE C62.45 performance evaluation standards. Wave forms – Per IEEE C62.41: Normal mode – 6kV 1.2/50μseconds, 500A 8/20μseconds, combination wave. Common mode – Category A & B ring wave tr = 0.5useconds, 100kHz | |||||
| Unit Input | Input circuit breaker for overload and short circuit protection | ||||||
| Overload Protection | Automatic UPS shutdown if overload exceeds 105% of nominal for 10 seconds and 130% for 300 ms. | ||||||
| Short Circuit | UPS output is cut-off immediately or input fuse blows. | ||||||
| Battery | Type | Hot swappable, sealed, maintenance-free lead acid | |||||
| Typ. Recharge Time | 8 hours (to 90% of full capacity) | ||||||
| Protection | Automatic cut-off and discharge protection. | ||||||
| Back-Up Time | 10 to 75 minutes (depending on load) | ||||||
| Physical | Net Weight lbs (kg) | 25 (11.3) | 62 (28) | 73.3 (33.3) | 42.3 (19.2) | 60 (27.2) | 66 (30) |
| Ship Weight lbs (kg) | 28.4 (12.9) | 67 (30.5) | 79 (35.7) | 51 (23) | 69 (31.4) | 75 (34) | |
| Dimensions ins (mm) WxDxH | 5.7x15.8x8.5 (145x400x215) | 7.7x18.5x15.2 (195x470x385) | 19x17.4x5.2 (485x440x130) | 19x21.7x5.2 (485x550x130) | |||
| Input Receptacle | IEC 320 type | Hardwire Terminals | IEC 320 type | Hardwire Terminals | |||
| No. of Output Receptacles | Four (4) NEMA 5-15R | Eight (8) NEMA 5-15R + Hardwire Terminals | Four (4) NEMA 5-15R | Four (4) NEMA 5-15R + Hardwire Terminals | |||
| Alarms | Battery Back-Up | Slow beeping sound (approx. 0.25Hz) | |||||
| Battery Low | Rapid beeping sound (approx. 1.00Hz) | ||||||
| Overload | Continuous beeping sound | ||||||
| Communication | DB9 Interface | RS-232 connection Bi-directional communication port, remote control & signaling | |||||
| Safety Agency | Approvals | UL1778, CUL, meets FCC, Class A requirements | |||||
| Environment | Ambient | 18,000 ft. max. elevation, 0-95% humidity non-condensing 32-104°F (0-40°C) | |||||
| Audible Noise (3 ft from surface) | <45dBA | <52dBA | <45dBA | <52dBA | |||
| Storage | 45000 ft max. elevation | ||||||
| Load VA/Watts | U1000-ONL 1000VA/700W | U2000-ONL 2000VA/1400W | U3000-ONL 3000VA/2100W | U1000-ORM 1000VA/700W | U2000-ORM 2000VA/1400W | U3000-ORM 3000VA/2100W |
|---|---|---|---|---|---|---|
| 250/175 | 54 | 97 | 105 | 49 | 74 | 99 |
| 500/350 | 24 | 52 | 68 | 25 | 39 | 68 |
| 750/525 | 16 | 36 | 51 | 18 | 29 | 48 |
| 1000/700 | 9 | 23 | 33 | 9 | 17 | 30 |
| 1250/875 | — | 15 | 25 | — | 13 | 23 |
| 1500/1050 | — | 12 | 21 | — | 10 | 20 |
| 1750/1225 | — | 10 | 18 | — | 8 | 17 |
| 2000/1400 | — | 8 | 17 | — | 7 | 15 |
| 2300/1610 | — | — | 14 | — | — | 12 |
| 2700/1890 | — | — | 11 | — | — | 10 |
| 3000/2100 | — | — | 9 | — | — | 7 |
| Part # | Description | Lashen's Price |
|---|
| Part # | Description | Lashen's Price |
|---|